Shop4handrail is now Shelley Automation Shop
Next Day Delivery Available
Expert Advice
Worldwide Shipping
Established 1997
Parker Accumulator Charging Kit (European) 10597-01 Item Code: 10597-01
£937.40
(Inc £1,124.88)
Parker Accumulator Charging Kit (European) 10597-04 PRE CHARGED SET C/W 0-25 & 0-250 BAR GAUGE - Charging hose, length 2,5 m - Connections for the accumulator: > 7/8 - 14 UNF > 5/8 - 18 UNF > 0.302 - 32 UNF > M28 x 1.5 > 1/4 BSP - Plastic protective case

Parker Accumulator Charging Kit (European) 10597-01

 

PRE CHARGED SET C/W 0-25 & 0-250 BAR GAUGE

 

Maintain Peak Performance: Pre-Charged Tester Set for Accumulators

Ensure Optimal Pre-Charge Pressure in Bladders, Pistons, and Membranes

This Pre-Charged Tester Set empowers technicians to efficiently manage the pre-charge pressure of hydraulic accumulators. It facilitates charging with nitrogen, testing existing pressure, and adjustments as needed.

Compatibility and Convenience:

  • Versatile Compatibility: Works seamlessly with various accumulator types, including bladders, pistons, and membranes.
  • Brand Adaptability: Suitable for OLAER, Fawcett Christie accumulators, and those equipped with 5/8" and 7/8" stem valves, Schrader valves, or screw plugs.
  • Simple Operation: Screws directly onto the accumulator's gas valve for a secure connection. The included 2.5-meter charging hose connects to a standard nitrogen cylinder. Disconnect the hose for pre-charge pressure checks only.

Integrated Features:

  • Multi-Function Gauge: Dual gauges (0-60 bar and 0-400 bar) provide clear pressure readings during charging and testing.
  • Enhanced Control: The tester incorporates a return valve on the charging hose for pressure regulation, a built-in release valve for safe depressurization, and a valve spindle for manipulating the gas valve or screw plug.
  • Comprehensive Connection Options: Multiple adapters ensure compatibility with various accumulators:
    • 7/8 - 14 UNF
    • 5/8 - 18 UNF
    • 0.302 - 32 UNF
    • M28 x 1.5
    • 1/4 BSP
  • Durable Protection: A sturdy plastic protective case safeguards the tester set during transport and storage.

Ideal Applications:

  • Maintaining hydraulic systems in construction, manufacturing, and agriculture.
  • Servicing equipment that relies on accumulators for pressure stabilization, shock absorption, and energy storage.
  • Optimizing hydraulic system performance by maintaining proper pre-charge pressure levels.

Invest in Efficient Maintenance:

The Pre-Charged Tester Set simplifies accumulator maintenance, saving time and ensuring optimal system performance. Contact us today to learn more and add this valuable tool to your maintenance toolbox!

Additional Notes:

  • Always refer to the manufacturer's specifications for your specific accumulator model and appropriate pre-charge pressure levels.


 

 

Parker Accumulator Charging Kit (European) 10597-01

 

PRE CHARGED SET C/W 0-25 & 0-250 BAR GAUGE

 

Maintain Peak Performance: Pre-Charged Tester Set for Accumulators

Ensure Optimal Pre-Charge Pressure in Bladders, Pistons, and Membranes

This Pre-Charged Tester Set empowers technicians to efficiently manage the pre-charge pressure of hydraulic accumulators. It facilitates charging with nitrogen, testing existing pressure, and adjustments as needed.

Compatibility and Convenience:

  • Versatile Compatibility: Works seamlessly with various accumulator types, including bladders, pistons, and membranes.
  • Brand Adaptability: Suitable for OLAER, Fawcett Christie accumulators, and those equipped with 5/8" and 7/8" stem valves, Schrader valves, or screw plugs.
  • Simple Operation: Screws directly onto the accumulator's gas valve for a secure connection. The included 2.5-meter charging hose connects to a standard nitrogen cylinder. Disconnect the hose for pre-charge pressure checks only.

Integrated Features:

  • Multi-Function Gauge: Dual gauges (0-60 bar and 0-400 bar) provide clear pressure readings during charging and testing.
  • Enhanced Control: The tester incorporates a return valve on the charging hose for pressure regulation, a built-in release valve for safe depressurization, and a valve spindle for manipulating the gas valve or screw plug.
  • Comprehensive Connection Options: Multiple adapters ensure compatibility with various accumulators:
    • 7/8 - 14 UNF
    • 5/8 - 18 UNF
    • 0.302 - 32 UNF
    • M28 x 1.5
    • 1/4 BSP
  • Durable Protection: A sturdy plastic protective case safeguards the tester set during transport and storage.

Ideal Applications:

  • Maintaining hydraulic systems in construction, manufacturing, and agriculture.
  • Servicing equipment that relies on accumulators for pressure stabilization, shock absorption, and energy storage.
  • Optimizing hydraulic system performance by maintaining proper pre-charge pressure levels.

Invest in Efficient Maintenance:

The Pre-Charged Tester Set simplifies accumulator maintenance, saving time and ensuring optimal system performance. Contact us today to learn more and add this valuable tool to your maintenance toolbox!

Additional Notes:

  • Always refer to the manufacturer's specifications for your specific accumulator model and appropriate pre-charge pressure levels.


 

 

Customer Reviews (0)